Fearture
1. Ideal choices for residential, community, and commercial AC EV charger
2.Input : 7kW(CE:L1+N+PE, UL:L1+L2+PE), 22kW(L1+L2+L3+N+PE)
3.IP54 & IK10 for indoor/outdoor applications
4.Firmware updates via OCPP remote connection
5.Optional internet connection for server management
6.Optional RFID card reader for user identification and management
7.(Dynamic) Load balancing
Model |
CHR 7/22(sockect) |
CHR 7/22(No display) |
Rated Input Voltage |
230VAC/Single Phase,380 VAC/ 3 phase |
240 VAC, 1-phase(AC Level 2) |
Output AC Current |
32A |
Frequency |
50Hz/60Hz |
Ground Fault Protection |
Lost input ground connection |
OCP |
< 35.2 A |
OVP |
>265VAC |
UVP |
< 190 VAC |
Residual Current Device (Type B optional) |
Type A:I△n 30 mA, Type B:I△n 30 mA+da 6mA Manual recovery after protection triggers |
CCID 20 |
|
Output Cable Length |
2~5m |
Regulation |
IEC 61851-1: 2017, IEC 61851-21-2 |
UL2202, UL2231-1/-2 |
Charging Plug/ Sockect |
IEC 62196-2:2016 type 2 plug, Type socket(shutter optional) |
SAE J1772 Type 1 Plug/Socket |
|
Thermal Protection |
YES |
IP Degrees |
YES |
IP Degrees |
IP55/IK10 |
Storage Temperature |
—40°~+70°C |
Operating Temperature |
—20°~+50°C |
Humidity at Operation Condiction |
95%RH max |
Humidity at Storage Condiction |
95%RH max |
Communications |
Wi-Fi(standard)/4G(optional) or (LAN optional) |
Backend Communication |
OCPP 1.6 JSON/SOAP |